Resultados: 12
#1
au:Santiago Júnior, Joel Ferreira
Filtros
Ordenar por
Página
de 1
Próxima
1.
A systematic review and meta-analysis of the clinical performance of implant-supported overdentures retained by CAD-CAM bars metaanalysis meta analysis implantsupported implant supported CADCAM CAD CAM
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Chappuis-Chocano, Ana Paula
; Venante, Helena Sandrini
; Costa, Rodrigo Moreira Bringel da
; Pordeus, Mariana Domingues
; Marcillo-Toala, Oscar Oswaldo
; Santiago Junior, Joel Ferreira
; Porto, Vinícius Carvalho
.
Abstract Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars. Objective: To evaluate the performance of IODs involving CAD-CAM bars. Methodology: A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: “How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?” The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI). Results: Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies. Conclusion: Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used. Currently implantsupported supported (IODs computeraided computer aided CADCAM CAD CAM (CAD-CAM Objective Methodology 202 databases PubMedMEDLINE PubMed MEDLINE PubMed/MEDLINE Science Library SciELO MetaAnalyses Meta Analyses PRISMA. PRISMA . (PRISMA) population intervention comparison PICO (PICO How practice practice? metaanalysis meta analysis twotailed tailed 95 CI. CI (CI) Results metaanalysis. analysis. them 100 CAD/CAMmilled CADCAMmilled CAD/CAM rehabilitation However complications periimplantitis, periimplantitis peri implantitis, implantitis peri-implantitis groups OHIP (OHIP life Conclusion Moreover 20 (PRISMA 9 (CI 10 CAMmilled 2 1
2.
Práticas de ressuscitação volêmica em unidades de terapia intensiva brasileiras: uma análise secundária do estudo Fluid-TRIPS
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Freitas, Flavio Geraldo Rezende de
; Hammond, Naomi
; Li, Yang
; Azevedo, Luciano Cesar Pontes de
; Cavalcanti, Alexandre Biasi
; Taniguchi, Leandro
; Gobatto, André
; Japiassú, André Miguel
; Bafi, Antonio Tonete
; Mazza, Bruno Franco
; Noritomi, Danilo Teixeira
; Dal-Pizzol, Felipe
; Bozza, Fernando
; Salluh, Jorge Ibrahin Figueira
; Westphal, Glauco Adrieno
; Soares, Márcio
; Assunção, Murillo Santucci César de
; Lisboa, Thiago
; Lobo, Suzana Margarete Ajeje
; Barbosa, Achilles Rohlfs
; Ventura, Adriana Fonseca
; Souza, Ailson Faria de
; Silva, Alexandre Francisco
; Toledo, Alexandre
; Reis, Aline
; Cembranel, Allan
; Rea Neto, Alvaro
; Gut, Ana Lúcia
; Justo, Ana Patricia Pierre
; Santos, Ana Paula
; Albuquerque, André Campos D. de
; Scazufka, André
; Rodrigues, Antonio Babo
; Fernandino, Bruno Bonaccorsi
; Silva, Bruno Goncalves
; Vidal, Bruno Sarno
; Pinheiro, Bruno Valle
; Pinto, Bruno Vilela Costa
; Feijo, Carlos Augusto Ramos
; Abreu Filho, Carlos de
; Bosso, Carlos Eduardo da Costa Nunes
; Moreira, Carlos Eduardo Nassif
; Ramos, Carlos Henrique Ferreira
; Tavares, Carmen
; Arantes, Cidamaiá
; Grion, Cintia
; Mendes, Ciro Leite
; Kmohan, Claudio
; Piras, Claudio
; Castro, Cristine Pilati Pileggi
; Lins, Cyntia
; Beraldo, Daniel
; Fontes, Daniel
; Boni, Daniela
; Castiglioni, Débora
; Paisani, Denise de Moraes
; Pedroso, Durval Ferreira Fonseca
; Mattos, Ederson Roberto
; Brito Sobrinho, Edgar de
; Troncoso, Edgar M. V.
; Rodrigues Filho, Edison Moraes
; Nogueira, Eduardo Enrico Ferrari
; Ferreira, Eduardo Leme
; Pacheco, Eduardo Souza
; Jodar, Euzebio
; Ferreira, Evandro L. A.
; Araujo, Fabiana Fernandes de
; Trevisol, Fabiana Schuelter
; Amorim, Fábio Ferreira
; Giannini, Fabio Poianas
; Santos, Fabrício Primitivo Matos
; Buarque, Fátima
; Lima, Felipe Gallego
; Costa, Fernando Antonio Alvares da
; Sad, Fernando Cesar dos Anjos
; Aranha, Fernando G.
; Ganem, Fernando
; Callil, Flavio
; Costa Filho, Francisco Flávio
; Dall´Arto, Frederico Toledo Campo
; Moreno, Geovani
; Friedman, Gilberto
; Moralez, Giulliana Martines
; Silva, Guilherme Abdalla da
; Costa, Guilherme
; Cavalcanti, Guilherme Silva
; Cavalcanti, Guilherme Silva
; Betônico, Gustavo Navarro
; Betônico, Gustavo Navarro
; Reis, Hélder
; Araujo, Helia Beatriz N.
; Hortiz Júnior, Helio Anjos
; Guimaraes, Helio Penna
; Urbano, Hugo
; Maia, Israel
; Santiago Filho, Ivan Lopes
; Farhat Júnior, Jamil
; Alvarez, Janu Rangel
; Passos, Joel Tavares
; Paranhos, Jorge Eduardo da Rocha
; Marques, José Aurelio
; Moreira Filho, José Gonçalves
; Andrade, Jose Neto
; Sobrinho, José Onofre de C
; Bezerra, Jose Terceiro de Paiva
; Alves, Juliana Apolônio
; Ferreira, Juliana
; Gomes, Jussara
; Sato, Karina Midori
; Gerent, Karine
; Teixeira, Kathia Margarida Costa
; Conde, Katia Aparecida Pessoa
; Martins, Laércia Ferreira
; Figueirêdo, Lanese
; Rezegue, Leila
; Tcherniacovsk, Leonardo
; Ferraz, Leone Oliveira
; Cavalcante, Liane
; Rabelo, Ligia
; Miilher, Lilian
; Garcia, Lisiane
; Tannous, Luana
; Hajjar, Ludhmila Abrahão
; Paciência, Luís Eduardo Miranda
; Cruz Neto, Luiz Monteiro da
; Bley, Macia Valeria
; Sousa, Marcelo Ferreira
; Puga, Marcelo Lourencini
; Romano, Marcelo Luz Pereira
; Nobrega, Marciano
; Arbex, Marcio
; Rodrigues, Márcio Leite
; Guerreiro, Márcio Osório
; Rocha, Marcone
; Alves, Maria Angela Pangoni
; Alves, Maria Angela Pangoni
; Rosa, Maria Doroti
; Dias, Mariza D’Agostino
; Martins, Miquéias
; Oliveira, Mirella de
; Moretti, Miriane Melo Silveira
; Matsui, Mirna
; Messender, Octavio
; Santarém, Orlando Luís de Andrade
; Silveira, Patricio Júnior Henrique da
; Vassallo, Paula Frizera
; Antoniazzi, Paulo
; Gottardo, Paulo César
; Correia, Paulo
; Ferreira, Paulo
; Torres, Paulo
; Silva, Pedro Gabrile M. de Barros e
; Foernges, Rafael
; Gomes, Rafael
; Moraes, Rafael
; Nonato filho, Raimundo
; Borba, Renato Luis
; Gomes, Renato V
; Cordioli, Ricardo
; Lima, Ricardo
; López, Ricardo Pérez
; Gargioni, Ricardo Rath de Oliveira
; Rosenblat, Richard
; Souza, Roberta Machado de
; Almeida, Roberto
; Narciso, Roberto Camargo
; Marco, Roberto
; waltrick, Roberto
; Biondi, Rodrigo
; Figueiredo, Rodrigo
; Dutra, Rodrigo Santana
; Batista, Roseane
; Felipe, Rouge
; Franco, Rubens Sergio da Silva
; Houly, Sandra
; Faria, Sara Socorro
; Pinto, Sergio Felix
; Luzzi, Sergio
; Sant’ana, Sergio
; Fernandes, Sergio Sonego
; Yamada, Sérgio
; Zajac, Sérgio
; Vaz, Sidiner Mesquita
; Bezerra, Silvia Aparecida Bezerra
; Farhat, Tatiana Bueno Tardivo
; Santos, Thiago Martins
; Smith, Tiago
; Silva, Ulysses V. A.
; Damasceno, Valnei Bento
; Nobre, Vandack
; Dantas, Vicente Cés de Souza
; Irineu, Vivian Menezes
; Bogado, Viviane
; Nedel, Wagner
; Campos Filho, Walther
; Dantas, Weidson
; Viana, William
; Oliveira Filho, Wilson de
; Delgadinho, Wilson Martins
; Finfer, Simon
; Machado, Flavia Ribeiro
.
Revista Brasileira de Terapia Intensiva
- Métricas do periódico
RESUMO Objetivo: Descrever as práticas de ressuscitação volêmica em unidades de terapia intensiva brasileiras e compará-las com as de outros países participantes do estudo Fluid-TRIPS. Métodos: Este foi um estudo observacional transversal, prospectivo e internacional, de uma amostra de conveniência de unidades de terapia intensiva de 27 países (inclusive o Brasil), com utilização da base de dados Fluid-TRIPS compilada em 2014. Descrevemos os padrões de ressuscitação volêmica utilizados no Brasil em comparação com os de outros países e identificamos os fatores associados com a escolha dos fluidos. Resultados: No dia do estudo, foram incluídos 3.214 pacientes do Brasil e 3.493 pacientes de outros países, dos quais, respectivamente, 16,1% e 26,8% (p < 0,001) receberam fluidos. A principal indicação para ressuscitação volêmica foi comprometimento da perfusão e/ou baixo débito cardíaco (Brasil 71,7% versus outros países 56,4%; p < 0,001). No Brasil, a percentagem de pacientes que receberam soluções cristaloides foi mais elevada (97,7% versus 76,8%; p < 0,001), e solução de cloreto de sódio a 0,9% foi o cristaloide mais comumente utilizado (62,5% versus 27,1%; p < 0,001). A análise multivariada sugeriu que os níveis de albumina se associaram com o uso tanto de cristaloides quanto de coloides, enquanto o tipo de prescritor dos fluidos se associou apenas com o uso de cristaloides. Conclusão: Nossos resultados sugerem que cristaloides são usados mais frequentemente do que coloides para ressuscitação no Brasil, e essa discrepância, em termos de frequências, é mais elevada do que em outros países. A solução de cloreto de sódio 0,9% foi o cristaloide mais frequentemente prescrito. Os níveis de albumina sérica e o tipo de prescritor de fluidos foram os fatores associados com a escolha de cristaloides ou coloides para a prescrição de fluidos.
Abstract Objective: To describe fluid resuscitation practices in Brazilian intensive care units and to compare them with those of other countries participating in the Fluid-TRIPS. Methods: This was a prospective, international, cross-sectional, observational study in a convenience sample of intensive care units in 27 countries (including Brazil) using the Fluid-TRIPS database compiled in 2014. We described the patterns of fluid resuscitation use in Brazil compared with those in other countries and identified the factors associated with fluid choice. Results: On the study day, 3,214 patients in Brazil and 3,493 patients in other countries were included, of whom 16.1% and 26.8% (p < 0.001) received fluids, respectively. The main indication for fluid resuscitation was impaired perfusion and/or low cardiac output (Brazil: 71.7% versus other countries: 56.4%, p < 0.001). In Brazil, the percentage of patients receiving crystalloid solutions was higher (97.7% versus 76.8%, p < 0.001), and 0.9% sodium chloride was the most commonly used crystalloid (62.5% versus 27.1%, p < 0.001). The multivariable analysis suggested that the albumin levels were associated with the use of both crystalloids and colloids, whereas the type of fluid prescriber was associated with crystalloid use only. Conclusion: Our results suggest that crystalloids are more frequently used than colloids for fluid resuscitation in Brazil, and this discrepancy in frequencies is higher than that in other countries. Sodium chloride (0.9%) was the crystalloid most commonly prescribed. Serum albumin levels and the type of fluid prescriber were the factors associated with the choice of crystalloids or colloids for fluid resuscitation.
https://doi.org/10.5935/0103-507x.20210028
273 downloads
3.
Vertical and Horizontal Misfit Analysis of 3-unit FDP Fabricated with Different Techniques and CAD/CAM Systems
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Pellizzer1, Eduardo Piza
; Mello, Caroline Cantieri de
; Gomes, Jéssica Marcela de Luna
; Santiago Júnior, Joel Ferreira
; Lemos, Cleidiel Aparecido Araújo
; Verri, Fellippo Ramos
.
Resumo O objetivo deste estudo foi avaliar a adaptação marginal vertical e horizontal de infraestruturas de prótese fixas de três elementos confeccionadas por diferentes técnicas e diferentes sistemas CAD/CAM. Um total de 40 infraestruturas foram confeccionadas e divididas em quatro grupos: fundição por cera perdida (G1); fundição por cera perdida com ponto de solda (G2); escaneamento óptico extraoral para escaneamento do modelo (3S/DWOS); escaneamento óptico intraoral (Cerec Bluecam/Sirona) (G4). Uma matriz metálica foi utilizada para simular uma prótese fixa de três elementos (com pôntico central). As infraestruturas do G1 e G2 foram fundidas em liga metálica de níquel-cromo (NiCr), enquanto que as infraestruturas de G3 e G4 foram fresadas em zircônia. Todos os grupos foram analisados quanto à adaptação marginal vertical e horizontal (sobrecontorno e subcontorno) em microscópio óptico tridimensional (Quick Scope, Mitutoyo). Os resultados apresentaram maiores valores de desadaptação marginal vertical no G1 comparados aos outros grupos (p<0,001). Em relação a desadaptação marginal horizontal, maiores valores de sobrecontorno foram observado no G3 em comparação com os demais grupos (p<0,001). Não foi observado valores de subcontorno para o G3, enquanto que os demais grupos não apresentaram diferença significante para o subcontorno (p> 0,05). Dentro das limitações do presente estudo, pode-se concluir que a técnica convencional após ponto de solda é uma alternativa viável para confecção de infraestruturas de próteses fixas de três elementos comparado ao uso de sistemas CAD/CAM, uma vez que as técnicas apresentaram valores de adaptação marginal vertical similares. Os sistemas CAD/CAM extraoral apresentou o maior desajuste horizontal (sobrecontorno) em comparação com outros grupos.
Abstract The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.
https://doi.org/10.1590/0103-6440201801916
1561 downloads
4.
Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Lemos, Cleidiel Aparecido Araujo
; Verri, Fellippo Ramos
; Santiago Júnior, Joel Ferreira
; Almeida, Daniel Augusto de Faria
; Batista, Victor Eduardo de Souza
; Noritomi, Pedro Yoshito
; Pellizzer, duardo Piza
.
Resumo O objetivo deste estudo foi avaliar diferentes sistemas de retenção (cimentada x parafusada) e configuração da coroas (unitárias x esplintadas) de próteses fixas implantossuportadas em relação a distribuição de tensões nos implantes/componentes e tecido ósseo pela análise de elementos finitos 3D. Quatro modelos 3D foram simulados com auxílio dos programas Invesalius, e Rhinoceros 3D, e SolidWorks. Os modelos foram confeccionados simulando bloco ósseo de região posterior da maxila (tipo ósseo III), com 3 implantes cone Morse com 4,0 mm de diâmetro e diferentes comprimentos, suportando prótese metalocerâmica de 3 elementos. Os modelos foram processados pelos programas FEMAP e NEiNastran sob força axial de 400 N e oblíqua de 200N. Os resultados foram plotados através de mapas de tensão de von Mises (vM) (implantes e componentes) e tensão máxima principal (TMP) (tecido ósseo). Sobre o carregamento axial, não foi observada diferenças entre os diferentes sistemas de retenção e tipo de prótese na distribuição das tensões nos implantes/componentes, porém, sobre o carregamento oblíquo as próteses cimentadas apresentaram melhor distribuição de tensões em comparação com as próteses parafusadas, enquanto que as próteses esplintadas apresentou uma tendência de redução das tensões no implante do primeiro molar. No tecido ósseo as próteses cimentadas apresentaram melhor distribuição das tensões em comparação com as próteses parafusadas, independente do carregamento. A esplintagem foi favorável somente para as próteses parafusadas, não havendo influência sobre as próteses cimentadas. As próteses cimentadas sobre implantes cone Morse apresentam melhor comportamento biomecânico nos implantes/componentes e tecido ósseo. A esplintagem foi efetiva somente nas próteses parafusadas sob carregamento oblíquo.
Abstract The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
https://doi.org/10.1590/0103-6440201801492
3339 downloads
5.
Three-Dimensional Finite Element Analysis of Varying Diameter and Connection Type in Implants with High Crown-Implant Ratio
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Moraes, Sandra Lúcia Dantas de
; Verri, Fellippo Ramos
; Santiago Júnior, Joel Ferreira
; Almeida, Daniel Augusto de Faria
; Lemos, Cleidiel Aparecido Araujo
; Gomes, Jéssica Marcela de Luna
; Pellizzer, Eduardo Piza
.
Resumo O objetivo deste estudo foi avaliar o efeito da variação do diâmetro e dos tipos de conexão na distribuição do estresse no osso cortical para implantes com a proporção coroa-implante. Seis modelos 3D foram simulados com os programas InVesalius, Rhinoceros 3D 4.0 e SolidWorks 2011. Os modelos foram compostos de osso da região mandibular posterior. Foram incluídos implantes de 8,5 mm de comprimento, diâmetro Ø 3,75 mm ou Ø 5,00 mm, e tipos de conexão como hexágono externo (EH), hexágono interno (IH) e cone Morse (MT). Os modelos foram processados usando os programas Femap 11.2 e NeiNastran 11.0 e usando uma força axial de 200 N e força oblíqua de 100 N. Os resultados foram registrados em termos da tensão principal máxima. O carregamento oblíquo mostrou alta tensão no osso cortical em comparação com a carga axial. Os resultados mostraram que os implantes com maior diâmetro apresentaram distribuição de tensões mais favorável, independentemente do tipo de conexão, enquanto que os implantes cone Morse apresentaram melhores distribuição de tensões comparado aos outros tipos de conexão, especialmente no carregamento oblíquo. Assim, os implantes de maior diâmetro foram mais favoráveis para distribuição das tensões na região de tecido ósseo cortical, enquanto que os implantes cone Morse apresentam menores concentrações de tensões do que as outras conexões.
Abstract The aim of this study was to evaluate the effect of varying the diameter, connection type and loading on stress distribution in the cortical bone for implants with a high crown-implant ratio. Six 3D models were simulated with the InVesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software programs. Models were composed of bone from the posterior mandibular region; they included an implant of 8.5 mm length, diameter Ø 3.75 mm or Ø 5.00 mm and connection types such as external hexagon (EH), internal hexagon (IH) and Morse taper (MT). Models were processed using the Femap 11.2 and NeiNastran 11.0 programs and by using an axial force of 200 N and oblique force of 100 N. Results were recorded in terms of the maximum principal stress. Oblique loading showed high stress in the cortical bone compared to that shown by axial loading. The results showed that implants with a wide diameter showed more favorable stress distribution in the cortical bone region than regular diameter, regardless of the connection type. Morse taper implants showed better stress distribution compared to other connection types, especially in the oblique loading. Thus, oblique loading showed higher stress concentration in cortical bone tissue when compared with axial loading. Wide diameter implant was favorable for improved stress distribution in the cortical bone region, while Morse taper implants showed lower stress concentration than other connections.
https://doi.org/10.1590/0103-6440201801746
4142 downloads
6.
Medication-related osteonecrosis of the jaw, osteoradionecrosis, and osteomyelitis: A comparative histopathological study
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
De Antoni, Carlos Cesar
; Matsumoto, Mariza Akemi
; Silva, Andréia Aparecida da
; Curi, Marcos Martins
; Santiago Júnior, Joel Ferreira
; Sassi, Laurindo Moacir
; Cardoso, Camila Lopes
.
Abstract It is largely known that some oral diseases can be diagnosed based upon their clinical manifestation combined with the patient's medical history and generally not depending on examination. This is the case of some bone diseases such as osteoradionecrosis of the jaw (ORNJ), osteomyelitis of the jaw (OMJ), and medication-related osteonecrosis of the jaw (MRONJ). The present study aimed to analyze the histopathological features of these specific bone diseases in order to evaluate similarities and differences. Forty-four bone specimens resected from each bone disease (22 cases of ORNJ, 6 cases of OMJ, and 16 cases of MRONJ) were analyzed by two experienced oral pathologists without prior knowledge of the diagnosis, considering bone tissue condition, inflammation, vascularization, and the presence of microorganisms. In addition, the examiners formulated a diagnostic hypothesis for each specimen. Many histopathological similarities were found among the diseases, especially considering the presence of necrotic bone, inflammation, and microorganisms. Statistically significant differences were detected in empty bone lacunae, which was decreased in ORN (p = 0.042), and considering neutrophil count, which was low in the MRONJ group (p ≤ 0.001). The Kappa coefficient was calculated and agreement was detected based on the histopathological parameters, but not for diagnostic suggestion (p=0.23). In conclusion, histopathological aspects of ORNJ, OMJ, and MRONJ do not permit a conclusive diagnosis, emphasizing the necessity of a detailed clinical report.
https://doi.org/10.1590/1807-3107bor-2018.vol32.0023
3614 downloads
7.
Medication-related osteonecrosis of the jaw. Introduction of a new modified experimental model
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Curra, Cláudia
; Cardoso, Camila Lopes
; Ferreira Júnior, Osny
; Curi, Marcos Martins
; Matsumoto, Mariza Akemi
; Cavenago, Bruno Cavalini
; Santos, Pâmela Letícia dos
; Santiago Júnior, Joel Ferreira
.
ABSTRACT PURPOSE : To evaluate a modified experimental model for medication-related osteonecrosis of the jaw (MRONJ) through the upper right central incisor extraction followed by intravenous bisphosphonate administration. METHODS: Forty five rats underwent the upper right central incisor tooth extraction were divided in 2 groups: Group I - experimental group, 30 rats received an intravenous administration protocol of zoledronic acid 35μg/kg into the tail vein every two weeks, totalizing four administrations, during eight weeks of administration, previously the extraction, and Group II - control group, 15 rats didn't received any medication before extraction. The groups were subdivided in postoperative periods: 14/28/42 days. Clinical analysis and microtomography were performed to verify the presence of osteonecrosis. In addition, descritive histological analysis of hematoxylin-eosin stained sections was performed to evaluate the presence of osteonecrosis or necrotic foci. RESULTS: Twelve (40%) rats, from experimental group, showed clinical signs of MRONJ (p=0.005), however, all samples showed imaginologic findings like osteolysis and loss of integrity of the cellular walls (p≤0.001). Microscopic evaluation revealed osteonecrosis areas with microbial colonies and inflammatory infiltrate (p≤0.001). In the control group, all animals presented the chronology of a normal wound healing. CONCLUSIONS: The presence of medication-related osteonecrosis of the jaw after maxillary central incisor extraction in rats. This new experimental model may be considered an option for the study of MRONJ.
https://doi.org/10.1590/S0102-865020160050000003
2508 downloads
8.
Systemic Trans- and Postoperative Evaluations of Patients Undergoing Dental Implant Surgery
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Goiato, Marcelo Coelho
; Santiago Junior, Joel Ferreira
; Pellizzer, Eduardo Piza
; Moreno, Amália
; Villa, Luiz Marcelo Ribeiro
; Dekon, Stefan Fiuza de Carvalho
; Carvalho, Paulo Sérgio Perri de
; Santos, Daniela Micheline dos
.
OBJECTIVE: The aims of this study were to examine the trans- and postoperative systemic characteristics of patients undergoing dental implant surgery and to investigate the relationship between pre- and post- surgery anxiety levels. MATERIAL AND METHODS: Thirty-nine patients were analyzed in 3 call centers to determine anxiety levels, pain levels, and preoperative and postoperative histories using the State-Trait (STAI) questionnaire. RESULTS: A total of 93 dental implants were installed, with a success rate of 100%. The most frequently reported systemic disease was hypertension. There was a significantly higher rate of effective clamping (torque) to the mandibular bone than to the maxillary bone. The association between postoperative surgical complications and longer operative time was not significant, but there was a significant correlation between the alteration of mouth opening and daily routine activities and a significant decrease in anxiety levels between the day of surgery and the postoperative time point (p =0.006). CONCLUSION: A longer surgical time was associated with surgery-related complications and with a higher anxiety index on the preoperative evaluation.
https://doi.org/10.6061/clinics/2016(03)07
1400 downloads
9.
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Moraes, Sandra Lucia Dantas de
; Verri, Fellippo Ramos
; Junior, Joel Ferreira Santiago
; Almeida, Daniel Augusto de Faria
; Mello, Caroline Cantieri de
; Pellizzer, Eduardo Piza
.
A proposta deste estudo foi avaliar a influência da altura da coroa de implantes de hexágono externo sobre o deslocamento e distribuição de tensões para o sistema implante/osso utilizando o método de elementos finitos. Os softwares InVesalius e Rhinoceros 4.0 foram usados para gerar o modelo de osso por meio de uma tomografia computadorizada. Cada modelo foi composto de um bloco ósseo com um implante (3.75 x 10.0 mm) com conexão de hexágono externo e coroas de 10 mm, 12.5mm e 15 mm em altura. Uma carga axial de 200 N e oblíqua (45°) de 100 N foram aplicadas. Os modelos foram resolvidos pelo software NeiNastram 9.0 e Femap 10.0 para obtenção dos resultados que foram visualizados por meio de mapas de deslocamento, de von Mises (coroa/implante) e tensão máxima principal (osso). A altura da coroa sob carga axial não influenciou o deslocamento e concentração de tensões, enquanto que a carga oblíqua aumentou a ação destes fatores. A maior concentração de tensões foi observada no pescoço do parafuso do implante no lado oposto à aplicação de carga. Esta tensão foi transferida para a interface coroa/plataforma/interface óssea. Os resultados deste estudo sugerem que o aumento da coroa amplia a concentração de tensões no tecido ósseo/implante, aumentando o deslocamento no tecido ósseo, principalmente sob carga oblíqua.
The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading.
https://doi.org/10.1590/0103-6440201302287
7270 downloads
10.
Classification of journals in the QUALIS System of CAPES URGENT need of changing the criteria!
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Andriolo, Adagmar
; Souza, Aécio Flávio Meireles
; Farias, Alberto Queiroz
; Barbosa, Alfredo José Afonso
; França Netto, Antonio Spina
; Hernandez, Arnaldo José
; Camargos, Aroldo F.
; Barraviera, Benedito
; Kadunc, Bogdana Victoria
; Caramelli, Bruno
; Campos, Carlos Eduardo Aguilera
; Brites, Carlos
; Nascimento, Dejair Caitano do
; Braile, Domingo M.
; Goldenberg, Dov Charles
; Baracat, Edmund Chada
; Kimura, Edna T.
; Marchiori, Edson
; Vieira, Eduardo de Paula
; Almeida, Eros Antônio de
; Jotz, Geraldo Pereira
; Camanho, Gilberto
; Friedman, Gilberto
; Cerri, Giovanni Guido
; Duarte, Ivomar Gomes
; Costa, Izelda Maria Carvalho
; Mello Júnior, João Ferreira de
; Faintuch, Joel
; Martinez, José Antônio Baddini
; Antonio Livramento, José
; Manso, José Eduardo Ferreira
; Amaral, José Luiz Gomes do
; Battistella, Linamara Rizzo
; Machado, Luís dos Ramos
; Moreira, Luiz Felipe P.
; Gebrim, Luiz Henrique
; Madeira, Marcelo
; Riberto, Marcelo
; Bastos, Marcus
; Falcão, Mário Cícero
; Conceição, Mario J. da
; Silva, Mauricio Rocha e
; Ruiz, Milton Artur
; Shibata, Milton K.
; Santiago, Mittermayer Barreto
; Andreollo, Nelson Adami
; Malafaia, Osvaldo
; Martins, Regina Helena Garcia
; Procianoy, Renato Soibelmann
; Baroudi, Ricardo
; Fuller, Ricardo
; Viebig, Ricardo Guilherme
; Nitrini, Ricardo
; Moura, Rita Cristina Mainieri R. de
; Dedivitis, Rogério
; Damião, Ronaldo
; Lianza, Sergio
; Rode, Sigmar de Mello
; Yoshida, Winston Bonetti
; Handar, Zuher
.
3236 downloads
Citado 9 vezes em SciELO
11.
Classificação dos Periódicos no Sistema QUALIS da CAPES - a Mudança dos Critérios é URGENTE!
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Andriolo, Adagmar
; Souza, Aécio Flávio Meireles
; Farias, Alberto Queiroz
; Barbosa, Alfredo José Afonso
; França Netto, Antonio Spina
; Hernandez, Arnaldo José
; Camargos, Aroldo F.
; Barraviera, Benedito
; Kadunc, Bogdana Victoria
; Caramelli, Bruno
; Campos, Carlos Eduardo Aguilera
; Brites, Carlos
; Nascimento, Dejair Caitano do
; Braile, Domingo M.
; Goldenberg, Dov Charles
; Kimura, Edna T
; Marchiori, Edson
; Vieira, Eduardo de Paula
; Almeida, Eros Antônio de
; Jotz, Geraldo Pereira
; Camanho, Gilberto
; Friedman, Gilberto
; Cerri, Giovanni Guido
; Duarte, Ivomar Gomes
; Costa, Izelda Maria Carvalho
; Mello Júnior, João Ferreira de
; Faintuch, Joel
; Martinez, José Antônio Baddini
; Livramento, José Antonio
; Manso, José Eduardo Ferreira
; Battistella, Linamara Rizzo
; Machado, Luís dos Ramos
; Moreira, Luiz Felipe P.
; Gebrim, Luiz Henrique
; Madeira, Marcelo
; Riberto, Marcelo
; Bastos, Marcus
; Falcão, Mário Cícero
; Conceição, Mario J. da
; Rocha e Silva, Mauricio
; Ruiz, Milton Artur
; Shibata, Milton K.
; Santiago, Mittermayer Barreto
; Andreollo, Nelson Adami
; Malafaia, Osvaldo
; Martins, Regina Helena Garcia
; Procianoy, Renato Soibelmann
; Baroudi, Ricardo
; Fuller, Ricardo
; Viebig, Ricardo Guilherme
; Nitrini, Ricardo
; Moura, Rita Cristina Mainieri R. de
; Dedivitis, Rogério
; Damião, Ronaldo
; Lianza, Sergio
; Rode, Sigmar de Mello
; Yoshida, Winston Bonetti
; Handar, Zuher
.
Arquivos Brasileiros de Cardiologia
- Métricas do periódico
3995 downloads
Citado 2 vezes em SciELO
12.
Classificação dos periódicos no Sistema Qualis da Capes: a mudança dos critérios é urgente!
Facebook Twitter
Facebook Twitter
- Outras redes sociais
- Google+
- StambleUpon
- CiteULike
- Mendeley
- Outras redes
- Métricas
Andriolo, Adagmar
; Barbosa, Alfredo José Afonso
; França Netto, Antonio Spina
; Hernandez, Arnaldo José
; Camargos, Aroldo F.
; Barraviera, Benedito
; Kadunc, Bogdana Victoria
; Caramelli, Bruno
; Campos, Carlos Eduardo Aguilera
; Brites, Carlos Roberto
; Braile, Domingo M.
; Goldenberg, Dov Charles
; Kimura, Edna T
; Marchiori, Edson
; Vieira, Eduardo de Paula
; Sampaio, Francisco J. B.
; Jotz, Geraldo Pereira
; Camanho, Gilberto
; Friedman, Gilberto
; Cerri, Giovanni Guido
; Duarte, Ivomar Gomes
; Costa, Izelda Maria Carvalho
; Mello Júnior, João Ferreira de
; Faintuch, Joel
; Martinez, José Antônio Baddini
; Livramento, José Antonio
; Manso, José Eduardo Ferreira
; Battistella, Linamara Rizzo
; Machado, Luís dos Ramos
; Moreira, Luiz Felipe P.
; Gebrim, Luiz Henrique
; Madeira, Marcelo
; Riberto, Marcelo
; Bastos, Marcus
; Falcão, Mário Cícero
; Silva, Mauricio Rocha e
; Ruiz, Milton Artur
; Shibata, Milton K.
; Santiago, Mittermayer Barreto
; Martins, Regina Helena Garcia
; Procianoy, Renato Soibelmann
; Baroudi, Ricardo
; Fuller, Ricardo
; Viebig, Ricardo Guilherme
; Nitrini, Ricardo
; Dedivitis, Rogério
; Damião, Ronaldo
; Lianza, Sergio
; Rode, Sigmar de Mello
; Yoshida, Winston Bonetti
; Handar, Zuher
.
Revista Brasileira de Hematologia e Hemoterapia
- Métricas do periódico
3073 downloads
Citado 2 vezes em SciELO
Exibindo
itens por página
Página
de 1
Próxima
Visualizar estatísticas de
Enviar resultado
Exportar resultados
Sem resultados
Não foram encontrados documentos para sua pesquisa
Glossário e ajuda para busca
Você pode enriquecer sua busca de uma forma muito simples. Use os índices de pesquisa combinados com os conectores (AND ou OR) e especifique cada vez mais sua busca.
Por exemplo, se você deseja buscar artigos sobre
casos de dengue no Brasil em 2015, use:ti:dengue and publication_year:2015 and aff_country:Brasil
Veja abaixo a lista completa de índices de pesquisa que podem ser usados:
Cód. do Índice | Elemento |
---|---|
ti | título do artigo |
au | autor |
kw | palavras-chave do artigo |
subject | assunto (palavras do título, resumo e palavras-chave) |
ab | resumo |
ta | título abreviado da revista (ex. Cad. Saúde Pública) |
journal_title | título completo da revista (ex. Cadernos de Saúde Pública) |
la | código do idioma da publicação (ex. pt - Português, es - Espanhol) |
type | tipo do documento |
pid | identificador da publicação |
publication_year | ano de publicação do artigo |
sponsor | financiador |
aff_country | código do país de afiliação do autor |
aff_institution | instituição de afiliação do autor |
volume | volume do artigo |
issue | número do artigo |
elocation | elocation |
doi | número DOI |
issn | ISSN da revista |
in | código da coleção SciELO (ex. scl - Brasil, col - Colômbia) |
use_license | código da licença de uso do artigo |