<sec><title>Background:</title><p>Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure.</p></sec><sec><title>Objective:</title><p>We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM).</p></sec><sec><title>Methods:</title><p>Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e´ wave, E/e´ ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson´s coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables.</p></sec><sec><title>Results:</title><p>Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m<sup>2</sup>. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e´ ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e´ ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase.</p></sec><sec><title>Conclusion:</title><p>The LAV is independently determined by LV filling pressures (E/e´ ratio) and mitral regurgitation in DCM.</p></sec>
<sec><title>Fundamento:</title><p>O Volume do Átrio Esquerdo (VAE) é preditor prognóstico em pacientes com insuficiência cardíaca.</p></sec><sec><title>Objetivo:</title><p>O objetivo do estudo foi avaliar os determinantes do VAE em pacientes com Cardiomiopatia Dilatada (CMD).</p></sec><sec><title>Métodos:</title><p>Incluídos 90 pacientes com CMD e fração de ejeção do Ventrículo Esquerdo (VE) ≤ 0,50. O VAE foi medido pela ecocardiografia tridimensional (eco3D). Foram avaliados frequência cardíaca, pressão arterial sistólica, volume diastólico e sistólico final do VE, fração de ejeção do VE, onda E mitral, onda e´ do anel mitral (Doppler tecidual), relação E/e´, dissincronia intraventricular, índice de dissincronia tridimensional e insuficiência mitral. O coeficiente de correlação de Pearson analisou a correlação do VAE com as variáveis avaliadas e a regressão linear múltipla as variáveis independentes associadas ao VAE.</p></sec><sec><title>Resultados:</title><p>A idade média foi 53 ± 11 anos, fração de ejeção do VE: 31,5 ± 8,0% e VAE: 39,2 ± 15,7 ml/m<sup>2</sup>. As variáveis que se correlacionaram com o VAE foram: volume diastólico final do VE (r = 0,38; p < 0,01), volume sistólico final do VE (r = 0,43; p < 0,001), fração de ejeção do VE (r = -0,36; p v 0,01), onda E (r = 0,50; p < 0,01), relação E/e´ (r = 0,51; p < 0,01) e insuficiência mitral (r = 0,53; p < 0,01). A análise multivariada identificou relação E/e´ (p = 0,02) e insuficiência mitral (p = 0,02) como os únicos preditores independentes do aumento do VAE.</p></sec><sec><title>Conclusão:</title><p>O VAE na CMD é determinado independentemente pelas pressões de enchimento do VE (relação E/e´) e insuficiência mitral.</p></sec>