OBJETIVO: Nosso objetivo é apresentar resultados a longo prazo da subsituição valvar por bioprótese de pericárdio bovino SJM-BiocorTM. MÉTODO: Entre 1992 e 2000, tiveram alta hospitalar, após substituição valvar por bioprótese de pericárdio bovino SJM-BiocorTM 304 pacientes. Idades eram de 15 a 83 anos (média: 60,6±14,3), sendo 50,3% do sexo masculino. Pacientes tiveram situação clínica atualizada e análise atuarial foi empregada no cálculo da sobrevida simples e livre de eventos. RESULTADOS: Em um seguimento total de 931,0 pacientes-ano, ocorreram 28 (9,2%) óbitos tardios, sendo cinco (1,6%) relacionados à bioprótese, sete (2,3%) cardíacos, quatro (1,3%) não-cardíacos e 12 (3,9%) de causa desconhecida. Eventos de bioprótese foram: endocardite: 18 (5,9%), degeneração fibrocálcica: 15 (4,9%), tromboembolismo: três (1,0%), hemólise: um (0,3%). Disfunção de bioprótese resultou em 16 (5,2%) reoperações, por degeneração fibrocálcica (nove), endocardite (seis) e tromboembolismo (um). Probabilidade de sobrevida foi 86,3±3,4%, no 5º, e 69,3±9,0%, no 10º ano pós-operatório. Idade jovem (<40 anos, n= 35) mostrou maior sobrevida em relação à mais idosa (>60 anos, n=187): 82,0±13,3% vs 58,8±13,6%, no 9º ano. Sobrevida livre de eventos foi 77,5±3,7%, no 5º, e 40,2±9,0%, no 10º ano. Probabilidade de falência estrutural de bioprótese foi 5%, no 5º ano, e 20%, no 10º; em aórticos, zero e 8%, respectivamente. A classe funcional (NYHA) atual é I para 88,5%, II para 9,1% e III para 2,4% dos pacientes. CONCLUSÃO: Implante de bioprótese de pericárdio bovino SJM-BiocorTM resulta em satisfatória perspectiva de sobrevida dos pacientes com doença valvar e apresenta baixa prevalência de disfunção de prótese.
OBJECTIVE: The objective of this work is to present long-term results of valve replacement using SJM-BiocorTM bovine pericardial bioprostheses. METHODS: From 1992 to 2000, 304 patients were discharged from hospital after bioprosthesis implantation. Ages ranged from 15 to 83 years (mean: 60.6 ± 14.3 years) and 50.3% were male. Patient deaths and events related to bioprosthesis (infection, thromboembolism and structural failure) were considered for estimation of cumulative probability of survival and event-free survival. RESULTS: Total follow-up was 931.0 patients-year. During follow-up there were 28 (9.2%) deaths. Causes were bioprosthesis failure in five (1.6%), cardiac in seven (2.3%), non-cardiac in four (1.3%), and unknown in 12 (3.9%) patients. Events related to bioprosthesis were: endocarditis: 18 (5.9%), fibrocalcic degeneration: 15 (4.9%), thromboembolism: three (1.0%), hemolysis: one (0.3%). Bioprosthesis dysfunctions resulted in 16 (5.2%) reoperations due to fibrocalcic degeneration (nine), endocarditis (six) and thromboembolism (one). Probability of survival was higher in the young population (< 40 years, n=35) when compared to the older group (> 60 year, n=187): 82.0 ± 13.3% vs. 58.8 ± 13.6% in the 9th year. Event-free survival was 77.5 ± 3.7% for 5th year and 40.2 ± 9.0% for 10th year. Overall estimative of structural failure for a SJM-BiocorTM was 5% in 5th year increasing to 20% in the 10th year. In the aortic position the values were zero and 8%, respectively. Considering current clinical conditions, 88.5% are in NYHA class I, 9.1% in class II and 2.3% in class III. CONCLUSIONS: SJM-BiocorTM bovine pericardial bioprostheses resulted in satisfactory survival of patients, related to low prevalence of bioprosthesis dysfunction.