OBJECTIVES: Because there was no program for the external evaluation of the quality of the screening for transfusion-transmitted infections (TTIs) in blood banks in Argentina, in 1999 the Hemotherapy Service of Garrahan Hospital, in Buenos Aires, launched an ongoing external evaluation program, with the support of the Pan American Health Organization and the Argentine Hemotherapy and Immunohematology Association. METHODS: A panel of 12 samples that were reactive to all the markers screened for in Argentine blood banks was distributed. The panel was delivered to 52 laboratories in 1999, 102 laboratories in 2000, and 118 laboratories in 2001. The participating laboratories were classified into one of four categories according to their performance: A: 0 or 1 false positive (FP) results; B: 2 or 3 FPs; C: 4 or more FPs; and D: at least 1 false negative result. Workshops were held with the participants in order to jointly analyze the results. RESULTS: Out of the laboratories that received the panel of samples, the percentage of laboratories that sent in their results was 92.3% in 1999, 92.2% in 2000, and 83.9% in 2001. These response levels demonstrate the interest in evaluation activities. However, the annual average percentage of the laboratories that received a "D" classification was very high (30%), which indicates that there are problems in the performance of TTI screening. This poor showing could be related to the difficulty in taking corrective measures throughout the system, given the large number of laboratories involved. CONCLUSIONS: Evaluations of this type should be included in Argentina's National Blood Program as a tool for the ongoing assessment of the blood banking situation, for decision-making, and for monitoring the quality of screening.
OBJETIVOS: Debido a la falta de un programa para la evaluación externa de la calidad del tamizaje de infecciones transmisibles por transfusión (ITT) en los bancos de sangre, el Servicio de Hemoterapia del Hospital Garrahan, de Buenos Aires, Argentina, inició en 1999 un programa continuo con el apoyo de la Organización Panamericana de la Salud (OPS) y la Asociación Argentina de Hemoterapia e Inmunohematología (AAHI). MÉTODOS: Se distribuyó un panel de 12 muestras con reactividad para todos los marcadores tamizados en los bancos de sangre argentinos. El panel se entregó a 52, 102 y 118 laboratorios en 1999, 2000 y 2001, respectivamente. Los laboratorios participantes se clasificaron según su desempeño en: A: menos de 2 resultados positivos falsos (RPF); B: de 2 a 3 PF; C: más de 3 RPF; y D: algún resultado negativo falso. Se efectuaron talleres con los participantes para analizar conjuntamente los resultados. RESULTADOS: Los porcentajes de respuesta de cada año fueron 92,3, 92,2 y 83,9, respectivamente; estos porcentajes de respuesta indican interés en las actividades de evaluación. Sin embargo, el promedio de los laboratorios con clasificación D resultó muy alto (30%), lo que evidencia la presencia de problemas en el desempeño del tamizaje de las ITT. Esto podría asociarse con la dificultad de tomar medidas correctoras en todo el sistema, dado el elevado número de laboratorios involucrados. CONCLUSIONES: Se deben incluir evaluaciones de este tipo en el Programa Nacional de Sangre para el diagnóstico continuo de la situación, la toma de decisiones y el seguimiento de la calidad del tamizaje.